JetNet-3008

Industrial 8-port Fast Ethernet Switch
Caratteristiche
  • 8x 10/100Base TX Ports with Autom MDI/MDI-X
  • Compact size with full power redundancy
  • 2.0Gbps Switch Fabric with excellent performance
  • QoS for packet forwarding precedence
  • Broadcast storm packet filtering
  • Port and power event alarm
  • Dual DC10~60V power inputs
  • Support 1.5KV Hi-Pot isolation protection
  • Aluminum case with IP31 grade protection
  • Operating temperature -25°~ 70°C (JetNet 3008 V3)
  • Operating temperature -40°~ 75°C (JetNet 3008-w V3);
  • Class1 Division2 certificate for hazardous locations
Manufacturer: Korenix Technology

Technology
Standard
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Fast Ethernet
IEEE 802.3x Flow Control and Back-pressure
IEEE 802.1p Class of Service (CoS)
System Performance
Switch Technology
Store and Forward Technology with 2.0Gbps Switch Fabric
System Throughput
1.49 Mega packets per second, 64bytes packet size
14,880 pps for 10Base-T
148,800 pps for 100Base-TX
(pps: Packet per Second) 
Transfer packet size
64 bytes to 1522bytes (includes 1522 bytes VLAN Tag)
MAC Address
2K MAC address table with auto learning
Packet Buffer
448 Kilo bits shared memory for packet buffer
Relay Alarm Output
Dry Relay output with 0.5A / 24VDC ability
Broadcast Storm Control
Default enabled.
Traffic threshold: 200 packets/Sec. @100Mbps; 20 packets/Sec. @10Mbps
Class of Service
Provides 2 packet forwarding Queues: High Queue (4~7), Low Queue (0~3)
Quality of Service
Default Enabled. Supports VLAN tag priority and IPv4 packet precedence
Event alarm relay
Provides port and power event alarm; Enabled by 9-PIN DIP switch

Interface
Enclosure Port
8 Fast Ethernet RJ-45
Alarm relay & Power inputL 6-pin removable terminal block
Cables
10Base-T: 2-pairs UTP/STP Cat. 3, 4, 5 cable, EIA/TIA_568B 100-ohm (100m)
100 Base-TX: 2-pairs UTP/STP Cat. 5 cable, EIA/TIA-568B 100-ohm (100m)

System Diagnostic LEDs
System
Power status (Green): On (power is on applying)
Alarm Output (Red): On (Output conductor is formed as a close circuit)
Ethernet port
RJ-45: Link (Green on) / Activity (Green blinks)
100Mbps: Link (Yellow on) / 10Mbps Link (Yellow off)

Power Requirements
System Power
2 x Redundant power input with polarity auto reverse protection
Power Input Range: DC 24V (10~60V)
Power System Type: Positive or Negative power source
Power Consumption
3.0 Watts / 24V ; Inrush current: 62.8A @ DC60V
Mechanical
Installation
DIN-Rail mount
Casing
Aluminum metal case with IP31 grade protection
Dimensions
55 (W) x 120(H) x 108 (D) / with DIN rail clip)
55 (W) x 120 (H) x 99 (D) / without DIN Rail Clip
Weight
0.555kg
 
Environmental
Operating Temperature
-25 ~ 70oC (JetNet 3008 V3) 
-40 ~ 75oC (JetNet 3008-w V3)
Operating Humidity
0% ~ 95% (non-condensing)
Storage Temperature
-40 ~ 85oC
Hi-Pot Insulation
AC 1.5KV for Port-Port / Port-Case / Port-Power, DC 1.5KV Power-Case

Regulatory Approvals
EMI
CISPR 16-1-2 / 16-2-1 / 16-2-3 / 22
FCC Part 15 Subpart B Class A, ANSI C63.4
Heavy Industrial IEC/EN61000-6-4
EMS
Heavy Industrial IEC/EN61000-6-2
IEC 61000-4-2, IEC61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8
Free Fall
IEC 60068-2-32 with packageNote-1
Warranty
Global 5 years
 
Note-1: Korenix's internal testing

Technology
Standard
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Fast Ethernet
IEEE 802.3x Flow Control and Back-pressure
IEEE 802.1p Class of Service (CoS)
System Performance
Switch Technology
Store and Forward Technology with 2.0Gbps Switch Fabric
System Throughput
1.49 Mega packets per second, 64bytes packet size
14,880 pps for 10Base-T
148,800 pps for 100Base-TX
(pps: Packet per Second) 
Transfer packet size
64 bytes to 1522bytes (includes 1522 bytes VLAN Tag)
MAC Address
2K MAC address table with auto learning
Packet Buffer
448 Kilo bits shared memory for packet buffer
Relay Alarm Output
Dry Relay output with 0.5A / 24VDC ability
Broadcast Storm Control
Default enabled.
Traffic threshold: 200 packets/Sec. @100Mbps; 20 packets/Sec. @10Mbps
Class of Service
Provides 2 packet forwarding Queues: High Queue (4~7), Low Queue (0~3)
Quality of Service
Default Enabled. Supports VLAN tag priority and IPv4 packet precedence
Event alarm relay
Provides port and power event alarm; Enabled by 9-PIN DIP switch

Interface
Enclosure Port
8 Fast Ethernet RJ-45
Alarm relay & Power inputL 6-pin removable terminal block
Cables
10Base-T: 2-pairs UTP/STP Cat. 3, 4, 5 cable, EIA/TIA_568B 100-ohm (100m)
100 Base-TX: 2-pairs UTP/STP Cat. 5 cable, EIA/TIA-568B 100-ohm (100m)

System Diagnostic LEDs
System
Power status (Green): On (power is on applying)
Alarm Output (Red): On (Output conductor is formed as a close circuit)
Ethernet port
RJ-45: Link (Green on) / Activity (Green blinks)
100Mbps: Link (Yellow on) / 10Mbps Link (Yellow off)

Power Requirements
System Power
2 x Redundant power input with polarity auto reverse protection
Power Input Range: DC 24V (10~60V)
Power System Type: Positive or Negative power source
Power Consumption
3.0 Watts / 24V ; Inrush current: 62.8A @ DC60V
Mechanical
Installation
DIN-Rail mount
Casing
Aluminum metal case with IP31 grade protection
Dimensions
55 (W) x 120(H) x 108 (D) / with DIN rail clip)
55 (W) x 120 (H) x 99 (D) / without DIN Rail Clip
Weight
0.555kg
 
Environmental
Operating Temperature
-25 ~ 70oC (JetNet 3008 V3) 
-40 ~ 75oC (JetNet 3008-w V3)
Operating Humidity
0% ~ 95% (non-condensing)
Storage Temperature
-40 ~ 85oC
Hi-Pot Insulation
AC 1.5KV for Port-Port / Port-Case / Port-Power, DC 1.5KV Power-Case

Regulatory Approvals
EMI
CISPR 16-1-2 / 16-2-1 / 16-2-3 / 22
FCC Part 15 Subpart B Class A, ANSI C63.4
Heavy Industrial IEC/EN61000-6-4
EMS
Heavy Industrial IEC/EN61000-6-2
IEC 61000-4-2, IEC61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8
Free Fall
IEC 60068-2-32 with packageNote-1
Warranty
Global 5 years
 
Note-1: Korenix's internal testing